Mouse Polling Rate Test
Run a polling rate test with continuous mouse movement. Compare repeated browser event-rate estimates; these are not raw USB polling measurements.
Browser-reported pointer event rate
Move continuously for eight seconds. No movement means no samples.
Why is my mouse polling rate lower in browser?
This polling rate test measures the rate of pointermove callbacks delivered to the page, not the raw USB report rate. A lower browser result alone does not prove a mouse fault.
Mouse polling rate test: Chrome vs Firefox
For a useful comparison, keep the same mouse, system settings, connection and motion. Run several eight-second trials in each browser with the tab visible. Record browser versions and compare medians rather than only peaks. There is no universal browser correction factor.
Polling rate checker limits
Browsers can merge pointer samples or align dispatch with rendering. This tool counts dispatched callbacks rather than recovering coalesced hardware samples. Background load, slow movement, power settings and a hidden tab can reduce the result.
Guides for this tool
See how this check fits into real troubleshooting workflows.
If the result is not what you expected
Keep focus in the test
Input tests capture events only inside the clearly marked active area.
Try a direct port
Reconnect wired devices without a hub and retest the same control.
Compare another app
OS shortcuts and browser event filtering can hide otherwise working controls.
How it works
- Start a short sampling window and move the mouse continuously in the test area.
- Pointer-event intervals are converted into instantaneous and summary rates.
- Review the browser-reported median, average, and peak values.
What this result cannot prove
- This is not the raw USB polling rate; browsers may merge or throttle pointer events.
- CPU load, display refresh, and operating-system settings affect the estimate.
Related tools
Frequently asked questions
How do I investigate a low polling rate test result?
Keep this tab visible, use consistent continuous motion and compare repeated medians. Check device software and try the same setup in another browser. Browser event coalescing and rendering load can limit the observed rate.
Can this verify an 8000 Hz mouse?
It cannot certify the raw USB rate. Use a suitable native measurement method for hardware verification and compare browser results as a separate signal.
What if the result is empty?
Repeat with continuous movement inside the sampling area and keep the tab visible for the whole run.